Skip to content

Cold Joints, Low Peel Strength, Blackened Joints: Is the Flux Really to Blame? ​

Cover

In brief

When stringing goes wrong, flux is usually the first suspect, but it is not always the real cause. This article first classifies common soldering defects, then uses a fishbone diagram to map four groups of suspects: flux, ribbon, cells, and equipment and process. It sets out a three-step troubleshooting method of "look at the pattern, swap, check the records", and explains how the fracture location in a peel test points to where the problem lies. It closes with a quick-reference table of flux-related defects for use on the line.

On the production line, when soldering goes wrong, flux is often the first thing blamed: try a new drum, add some thinner. Sometimes that works, but more often the problem comes back a few days later. Flux is a common cause of soldering defects, but not the only one. In this article we take the line's perspective and look at how to judge systematically whether a problem really is the flux.

01Classify the defect first: what are you actually seeing? ​

Before troubleshooting, describe the symptom clearly. "Bad soldering" is too vague, and different symptoms point to very different causes. Common soldering defects fall into these groups:

Defect typeTypical featuresCommon inspection methods
Cold / false jointRibbon appears attached but has no reliable metallurgical bond; comes off at a touch or is partly unsolderedEL, peel test, visual
Low peel strengthLow average peel force, or wide scatter along one ribbonPeel test (state the peel angle)
Over-solderingTemperature too high or time too long, causing breakage, microcracks or finger lift-offEL, visual, microscopy
Abnormal joint appearanceBlackening, white spots or crystalline residue around the joint, or solder ballsVisual, microscopy
Ribbon offset / slipRibbon off the finger position, or moving after solderingVisual, vision inspection

Table 1. Classification of common soldering defects

Peel testing deserves a special note. EN 50461 sets a minimum of 1 N per mm of joint width but does not specify the peel angle. A Fraunhofer ISE study found that the same type of joint gives very different forces at different angles: about 9.7 N on average at 45° versus about 3.1 N at 90°, roughly three times as much, with about 2.5 N at 135° and 3.5 N at 180°. Before comparing peel data, always confirm that the peel angle, speed and fixture are the same. With fine round-wire ribbon, joint width is hard to define in the first place, and many companies set internal limits as force per wire instead, which makes it even more important to align definitions before comparing across plants.

02Four suspects ​

Soldering is the combined result of ribbon, cell, flux and equipment/process. A fishbone diagram maps the common causes:

Figure 1. Four "suspects" behind soldering defects

Figure 1. Four "suspects" behind soldering defects

  • Flux: drift in bath concentration (evaporation, water uptake), too much or too little flux, batch-to-batch variation, activation window not matched to the temperature profile.
  • Ribbon: coating oxidation, variation in coating thickness or composition, moisture during storage, poor dimensions or flatness. We covered these in detail in our ribbon series.
  • Cell: poor finger solderability, abnormal paste or firing condition, surface contamination, and incoming issues such as microcracks and warpage.
  • Equipment / process: temperature profile drift, pin or hold-down plate condition, heating power decay, changes in preheat and cooling settings.

These four groups often look alike: a cold joint may come from low flux concentration, from oxidised ribbon or from a drop in heating power. Drawing a conclusion from one symptom alone easily leads to "arresting the wrong suspect".

03A three-step method: pattern, swap, records ​

Figure 2. Three-step approach to troubleshooting soldering defects

Figure 2. Three-step approach to troubleshooting soldering defects

  • Step 1, look at the pattern: first establish where the problem is and when it started. If it is concentrated on one machine or track, check that equipment and its flux bath first. If it appeared suddenly after a certain point in time, check batch changes, material changes and maintenance around that time. If the whole line is slowly getting worse, check bath concentration and shop-floor temperature and humidity first.
  • Step 2, swap: on the affected machine, change one variable at a time: a new drum of flux or a freshly made bath, a new ribbon batch, a new cell batch, or run the same materials on another machine. Change only one variable at a time. Whatever the problem follows is the main suspect.
  • Step 3, check the records: use data to lock in the cause: bath acid value and specific gravity, top-up and bath-change logs, temperature profiles and heating power, maintenance logs, and material batch changes. The baselines and daily records recommended in articles 03 and 05 become decisive here.

These three steps pin most problems to one main cause. If the problem disappears after swapping the flux, send the old bath for testing and compare acid value, solids content and appearance to tell whether the issue lies in bath management or in the incoming batch.

Bottom line

The key to troubleshooting is controlling variables. Narrow the scope with the pattern, verify by swapping one thing at a time, then confirm with records, so that "we changed the flux and it happened to get better" does not mislead you.

04Reading the cause from the peel fracture ​

A peel test is more than one number. Once the ribbon is pulled off, the layer where it failed often says more than the force value itself.

Figure 3. After a peel test, check which layer failed (schematic)

Figure 3. After a peel test, check which layer failed (schematic)

  • Failure between ribbon and solder: poor bonding between the solder coating and the copper core, or at the coating surface; typical of oxidised or damp ribbon or insufficient wetting.
  • Failure between solder and finger: the solder did not wet the finger well, and almost no solder remains on the finger surface. This is the failure location most closely linked to flux, usually from insufficient activity, too little flux or too low a temperature.
  • Failure between finger and silicon: the finger is lifted together with the solder, exposing the wafer surface. This is usually a paste adhesion problem with no direct link to flux.
  • Tearing inside the silicon: the joint is stronger than the substrate, but rule out artefacts from poor fixturing.

Real fracture surfaces are often a mix of modes, so combine microscopy with the peel curve. The Fraunhofer ISE study observed a uniform cohesive fracture inside the cell metallisation in all of its 180° peel tests. A separate study from a Korean group used shear tests to look at ageing: after 1,000 hours at 90–150°C, shear strength fell from about 240–270 MPa to about 130 MPa, the fracture location shifted between the solder/sintered-Ag and sintered-Ag/silicon interfaces, and the loss of strength came mainly from weakened bonding between sintered silver and silicon. Peel strength and fracture surfaces both change with ageing, so take the sample's history into account.

Finally, here is a quick-reference table of common flux-related defects for use on the line:

SymptomPossible flux-related causeSuggested check
More cold joints on one machineLow bath concentration on that machine, clogged nozzle or too little fluxMeasure that bath's acid value, check nozzle or brush, compare with a fresh bath
Peel strength drops after a batch changeFlux batch variationCompare COA with internal baseline; cross-solder old and new batches
White spots or heavy residue around jointsToo much flux, concentrated bath, high solids or water uptakeMeasure acid value and solids, adjust dosage, watch how residue changes
Solder balls, spatterSolvent or water not fully evaporated, insufficient preheatCheck preheat temperature and drying/blow-off; check the bath for water uptake
Ribbon slip or offsetToo much liquid flux reducing positional stabilityReduce dosage or add pre-solder drying and watch for improvement
Blackened jointsResidue overheated by excessive temperature, or abnormal activator decompositionCheck the temperature profile, rule out over-soldering, then compare with another flux
EL darkening near the ribbon after ageingFlux overflow or residue corrosion (TOPCon and HJT are more sensitive)Inspect for overflow traces under the microscope; compare in cell-level damp heat

Table 2. Quick-reference table for flux-related defects

Note that the table lists only possible flux-related causes. The same symptoms may come from ribbon, cells or equipment. Use the table to narrow the scope; the final conclusion still has to be confirmed by swap testing.

Summary

Classify the symptom first, read the cause from the pattern, lock it in by swapping, and confirm it with records. The peel fracture surface is an important clue to wetting problems.

06Final thoughts ​

Three things to remember when troubleshooting soldering defects:

  • Don't jump to conclusions: flux is a common suspect, but cold joints and low peel strength can just as well come from ribbon, cells or equipment;
  • Control variables: look at the pattern, swap, check the records, and change one variable at a time so the problem "follows its cause";
  • Read the fracture: failure between solder and finger is most likely linked to flux wetting; failure between finger and silicon points more to the cell paste.

This article covered defects you can see directly on the line. Another class of problem is more hidden: modules look fine when they ship, but problems emerge gradually in DH, TC and HF ageing tests or in the field. In the next article we look at the role of flux in module reliability, using failure analysis cases to show how corrosion, electromigration and rising series resistance develop step by step.

Do you have a "secret weapon" for troubleshooting soldering defects? We would be glad to hear from you.

Calculation notes / data basis: 1. Peel forces at different angles are the mean values from Eitner and Rendler (2014): about 9.74 N at 45°, 3.14 N at 90°, 2.46 N at 135° and 3.49 N at 180°. "About three times" is the 45°/90° ratio (9.74 ÷ 3.14 ≈ 3.1); the values apply only to that study's samples and conditions. 2. The ageing data are from Kang et al. (2019) and are shear strengths (MPa), a different kind of measure from peel force (N or N/mm), so the two cannot be compared directly. 3. The "≈3×" on the cover is the 45°/90° ratio in note 1.

References

  1. U. Eitner, L. C. Rendler: Peel Testing of Ribbons on Solar Cells at Different Angles: Consistent Comparison by Using Adhesive Fracture Energies, 29th EU PVSEC, Fraunhofer ISE, 2014, https://www.ise.fraunhofer.de/content/dam/ise/de/documents/publications/conference-paper/29-eupvsec-2014/Eitner_5DV340.pdf
  2. EN 50461: Solar cells — Datasheet information and product data for crystalline silicon solar cells (minimum peel force 1 N/mm)
  3. M.-S. Kang, Y.-J. Jeon, Y.-E. Shin: Bonding Strengths and Thermal Degradation of Photovoltaic Module Ribbon Solder Joints, International Journal of Precision Engineering and Manufacturing-Green Technology 6 (2019) 489–496, https://link.springer.com/article/10.1007/s40684-019-00045-0
  4. Renewable Energy World: Bond testing of solar cell interconnections
  5. pv magazine: New study confirms sensitivity of heterojunction solar cells to soldering flux, 2025
  6. pv magazine Australia: UNSW study shows impact of soldering flux on TOPCon solar cell degradation, 2025
PV Materials Lab
PV Materials Lab (光伏新材料研究所)
A PV R&D and technology team with 10+ years of experience | In-depth technical knowledge sharing
Materials · Reliability · Failure Analysis · Standards & Certification · Products · Processes
Exploring AI + PV; collaboration welcome

Disclaimer:
1. Original content reflects the authors' personal views only, is for reference only and does not constitute investment advice.
2. Reposted and cited content is credited to its source, out of respect for original work.
3. Some content was produced with AI assistance (chart generation, data retrieval, concept explanations, etc.); the core framework and key content were written by our technical team and reviewed by people.
4. If anything is inaccurate or infringes your rights, please leave a message or contact us and we will deal with it.