How LONGi Reached 680 W in the Same Module Footprint

PV Materials Lab · Industry News and Analysis
LONGi introduced its Hi-MO X10 Full-Screen Triple-Protection module at the Ma Ge Energy Channel year-end keynote on November 17, 2026, and published the announcement the next day. The module uses HPBC 2.0 back-contact cells and measures 2,382 × 1,134 mm. LONGi lists a maximum front-side power of 680 W, a corresponding conversion efficiency of 25.2%, and 670 W as its main available power bin. The key figures reported by TrendForce and Solarbe match those in the company release.[1–3]
The footprint stayed the same, but LONGi says the module gained 759.3 cm² of front-side light-receiving area, bringing its front-side coverage to 98.58%. The extra area comes from gaps between cells, space occupied by busbars, spacing between strings, and margins at the module edge. Using that space requires control of soldering stress, layout tolerances after lamination, and insulation at the edge.[1]
01 What 680 W and 670 W Mean
The module footprint is approximately 2.701 m². Using the full footprint and an irradiance of 1,000 W/m², 680 W gives approximately 25.17%, which rounds to the reported 25.2%. The same calculation gives approximately 24.80% for 670 W. The 25.2% figure therefore belongs with the 680 W top bin. This arithmetic checks that the figures agree. The release did not specify the measurement conditions or provide a third-party power report number. Buyers can verify the front-side rating at standard test conditions (STC) from the datasheet and test report for the exact model.[1–3]
Front-side coverage describes how much of the module face can receive light for generation. Conversion efficiency measures how much of the incident light power is converted to electrical output. The additional 759.3 cm² equals about 2.81% of the footprint. If both coverage figures use the same denominator and definition, that translates to about 2.81 percentage points of additional coverage. The wattage gain also depends on cell efficiency, shading and interconnection losses.[1]
02 Where LONGi Recovered Front-Side Area
The first change closes the visible gaps between adjacent cells in a string. LONGi slightly overlaps the cells, uses a film to hold the cells and ribbons in place, then solders them together at low temperature. Overlapping creates a step at the cell edge. Ribbons and silicon expand at different rates as temperature changes, so stress can build up at the overlap. Heat input, the height difference between cells and the loads on the interconnects all matter. LONGi reports a 130 μm step height, a tilt of about 0.07°, a 53% reduction in soldering stress and a gain of 178 cm² in light-receiving area. The stress figure comes from LONGi.[1]
The second change moves the busbars to the rear and reduces their thickness, recovering another 294 cm² at the front. The announcement cites a combined busbar and ribbon thickness of approximately 500 μm to explain the difficulty of moving the busbars. A thicker local stack can concentrate pressure on nearby cells during lamination. The 500 μm figure illustrates that design constraint. The announcement leaves the final thinned stack thickness unspecified.[1]

Figure 1. Additional light-receiving area within the same footprint. The last two changes are shown as a combined balance derived from LONGi’s total.
The other two changes address the gap between strings and the edge margin from the outer cells to the frame. LONGi tightened the nominal string spacing from approximately 1.48 mm to 1 mm by refining the layout process. It also upgraded the insulation materials to bring what it describes as the cell-to-frame insulation distance below 9 mm. These dimensions refer to different locations and require separate checks. For the 1 mm nominal string spacing, the distribution of minimum gaps after lamination matters in production. Placement and lamination shifts can combine to leave local gaps smaller than the nominal value.[1]
With the busbars on the rear, the design also has to manage rear shading. LONGi lists round ribbons, less local insulation coverage and a frame profile that avoids shading the cells. The company reports 2.5% more rear light-receiving area, a bifaciality improvement of more than 2%, and bifaciality of up to 85%. Bifaciality is the ratio of rear to front response under specified test conditions. The energy gain on a commercial roof also depends on roof reflectance, mounting height and rear shading.[1,3]
03 Which Insulation Path Does 9 mm Refer To
LONGi says the IEC requirement it cites called for a cell-to-frame insulation distance of at least 12.9 mm and that upgraded materials brought the distance below 9 mm. The announcement does not identify the edition, clause or insulation cross-section. The geometric distance on a drawing, creepage measured along an insulating surface and clearance measured through air each need to be checked along the applicable path. A cemented joint or another insulation construction would also require the applicable clause and validation evidence. The published dimensions alone leave the assessment path unclear.[1,5]
When a material change frees up space, assess the insulation in the assembled module. Match the material specification and thickness to the certified bill of materials, and use the drawing to identify both ends of the shortest path. Combining cell placement error, movement during lamination and frame assembly tolerances shows how much margin remains in production. A single sample with perfectly centered cells can miss the minimum created by tolerance stack-up.
Around the same time, Kiwa PI Berlin told PV Tech that some manufacturers retained their existing glass and frame dimensions when switching to larger M10R cells, reducing margins at cell edges or between strings. The interviewee said certain projects had spacing close to or below the UL requirements he cited. The observations concern projects Kiwa encountered. LONGi did not disclose the wafer size for this module, and the available information does not establish that the two designs are comparable. The practical takeaway is to match nominal drawing dimensions, the smallest gaps measured after lamination and the acceptance values in the applicable standards.[4]
04 How the Three Protection Features Can Be Verified
For hot spots, LONGi says it increased the number of diode-like bypass structures on HPBC 2.0 cells to provide a path that diverts current when part of a cell is shaded. It reports a maximum measured hot-spot temperature of 100 °C or less across several scenarios. The announcement omits the shading configuration, irradiance, sample count and testing organization. The figure applies to the scenarios described by the company.[1]
For arcing, the junction box uses laser fusion welding to reduce the risk of poor electrical contact at an internal welded joint. For microcracks, low-temperature soldering and thinner busbars address thermal stress and localized pressure during manufacture. Joint quality and the stability of the electrical connection after aging are relevant to the former. Electroluminescence (EL) imaging before and after lamination or mechanical loading can help assess the latter.[1]
LONGi says the product passed certification and tests with TÜV SÜD and TÜV Rheinland. It lists IEC 61215, IEC 61730, PID, LID, LeTID, severity level 6 salt mist, ammonia, dust and hail with 25 mm and 35 mm ice balls. IEC 61215 covers design qualification, while IEC 61730 covers safety qualification. The announcement does not identify the certified models, certificate numbers, reports, test conditions or which body covered which tests. It also leaves open whether its “2× PID” label refers to test duration, voltage or some other condition.[1,5–7]
For hail testing, check the impact speed or energy and impact locations alongside the ice-ball diameter, then look at the post-impact visual, power and insulation criteria. For a module with tighter spacing, the results and the construction of the tested sample together help assess how the layout holds up under impact.[7]
05 Conclusion
LONGi has extended the front-side advantage of HPBC 2.0 cells into module layout and interconnection. In a footprint of roughly 2.70 m², it lists 670 W as the main available bin, 680 W as the top bin and 98.58% front-side coverage. Using LONGi’s claimed 20 W advantage over mainstream TOPCon at the same module count yields approximately 20 kW of additional DC capacity for every 1,000 modules. LONGi estimates that a 10,000 m² roof could gain 59 kW of capacity, 65,000 kWh per year and CNY 1.01 million in electricity revenue over 30 years. Those figures are company projections. The release does not fully specify the comparator or the assumptions behind the revenue calculation.[1]
In our view, the engineering value of the release is that it brings power density, layout margins and insulation design together in one product. For a commercial rooftop project, the 670 W main bin is the starting point for a same-roof layout comparison, followed by a check of the datasheet, key bill of materials (BOM) and TÜV certificate scope for the model being supplied. Verifying the insulation path and the minimum tolerances with the tighter edge margin tells buyers more about the value of the design than the peak rating alone.
Data Notes
Sources were checked on November 19, 2026. The efficiency calculation uses the full module footprint and an incident irradiance of 1,000 W/m². LONGi did not specify the model used as the baseline for the front-area gain, improved bifaciality or TOPCon comparison. The release also omits the cell count, wafer size, module thickness and weight, and shipment volumes for this model.
References
- [1] LONGi | Hi-MO X10 Full-Screen Triple-Protection release
- [2] Solarbe | Product launch coverage
- [3] TrendForce | Product launch coverage
- [4] PV Tech | Kiwa PI Berlin interview on spacing with M10R cells
- [5] IEC 61730-1 | Construction requirements for module safety qualification
- [6] IEC 61215-1 | Module design qualification requirements
- [7] IEC 61215-2 | Module design qualification test procedures