Skip to content

What Changes When PV Glass Reaches 1.6 mm ​

Thinner glass changes more than weight. Understanding the value of a 0.4 mm reduction requires connecting material properties, manufacturing, module mechanics, and project economics.

Cover

In photovoltaics, 1.6 mm glass is often framed in two very different ways. One sees lower weight and material use as evidence of progress; the other sees thinness as an inevitable reliability problem. Thickness alone supplies too little information for either conclusion.

Glass is both a light-transmitting protective layer and a structural part of a module. Removing 0.4 mm changes material consumption, manufacturing tolerances, and the way the whole module carries load. The useful question is how these changes combine in a product intended for long service.

01 Separate glass weight savings from module weight savings ​

Start with a simple calculation. At a glass density of 2,500 kg/m³, the glass in a 2.0 + 2.0 mm construction weighs approximately 10 kg/m². A 1.6 + 1.6 mm construction weighs 8 kg/m², reducing glass mass by 20%. Over 2.6 m², the saving is 5.2 kg.[1]

A module also contains its frame, encapsulant, cells, ribbons, and junction box. If a hypothetical module originally weighs 32 kg, and its area and all other materials remain unchanged, thinning the glass brings its mass to approximately 26.8 kg, a reduction of about 16.3%. This is a calculation example, not a product measurement. Describing a 20% glass saving as a 20% module saving changes the denominator.

Saving 5.2 kg can ease handling and reduce the added permanent load of a rooftop system. It may improve installation conditions in weight-sensitive projects. Nevertheless, rooftop suitability still requires assessment of rails, clamps, wind uplift, and snow loads. Mass per square metre of module area is also different from added load per square metre of total roof area.

Commercial products already illustrate the approach. In 2024, Trinasolar announced mass production of the NEG18R.28 with 1.6 + 1.6 mm glass, dimensions of 1,961 × 1,134 mm, and a mass of 23.5 kg.[2] This establishes that thin glass can be part of a complete product. Comparisons with other modules must still account for area and construction.

Another easily overlooked scale is area: equal power does not imply equal dimensions. Product comparisons can examine mass per square metre, mass per watt, and installed power density over the roof. If power, area, or layout changes alongside unit weight, the project-level benefit must be recalculated.

Figure 1. One thickness change, three different denominators. Glass mass uses 2.6 m². Total-module mass assumes a 32 kg starting point with all other materials unchanged. Stiffness applies only to an individual sheet of the same material, not a complete module.

Figure 1. One thickness change, three different denominators. Glass mass uses 2.6 m². Total-module mass assumes a 32 kg starting point with all other materials unchanged. Stiffness applies only to an individual sheet of the same material, not a complete module.

02 Thinner does not necessarily mean easier to manufacture ​

Using less glass reduces the batch and molten material required per unit area. Finished-product cost, however, also depends on yield, throughput, and processing energy. Extra breakage, rework, or strengthening electricity can consume part of the material saving. A 20% thickness reduction therefore does not establish a 20% reduction in cost or total energy consumption.

Primary production must control thickness, flatness, and surface quality consistently. Edge-finishing damage, roller contact, and handling cups can then influence flaws during downstream processing. Glass fracture is highly sensitive to defects, so two nominally identical 1.6 mm sheets can perform differently when their production quality differs.[1]

Strengthening is particularly demanding. Thermal strengthening uses heating and rapid cooling to leave residual surface compression that resists crack opening. A thinner sheet loses its surface-to-core temperature gradient more quickly. Stronger cooling must also avoid distorting the hot, soft glass. Heat extraction, uniformity, and flatness must be controlled together; simply increasing blower power is insufficient.[3]

Optical performance deserves a separate comparison. Low-iron composition, surface texture, antireflection coatings, and thickness serve different functions. With identical composition and coating, thinning reduces bulk absorption, but differences between products cannot all be attributed to 0.4 mm. Material savings and optical gains each require clearly matched comparison conditions.

Primary processing and the intended position in the module also matter. Front glass places particular demands on transmission, surface treatment, and front-side impact; rear glass can involve different transparency, printing, and electrical-packaging requirements. Matching 1.6 mm labels do not establish identical processing configurations, or show that any two sheets can form a qualified module.

03 Strength stiffness and hardness describe different properties ​

A common misunderstanding is that sufficiently strengthened glass will prevent additional module bending. Strength concerns the load or stress that causes failure. Stiffness concerns deformation under load. Hardness primarily describes resistance to indentation and surface scratching. These properties are not interchangeable.

For an individual thin plate made from the same material, bending stiffness is D = Et³/[12(1 − ν²)], where E is Young's modulus, t is thickness, and ν is Poisson's ratio. Reducing thickness from 2.0 to 1.6 mm produces a ratio of (1.6/2.0)³ = 0.512, approximately 49% lower. Strengthening improves resistance to fracture without a corresponding near-doubling of elastic modulus.

This does not mean that the complete module must deflect twice as much. It demonstrates that mass reduction and deformation do not follow the same proportional relationship: mass scales approximately with thickness, while individual-sheet bending stiffness scales with thickness cubed. Introducing 1.6 mm glass therefore calls for renewed attention to module design.

Two rulers made from the same material but with different thicknesses provide an analogy. Under the same small force, the thinner ruler bends further even though neither breaks. In a module, deformation changes the strain experienced by the cells and interconnects. Reliability assessment must examine both glass fracture and the demands placed on internal materials.

04 Reliability depends on the assembled module ​

A cross-section of a glass-glass module reveals glass, encapsulant, cells, and interconnects. The ability of the two glass sheets to act together depends on interlayer shear transfer: how forces pass between adjoining layers as they try to slide relative to one another. The frame and rails determine how load reaches the supports. Nominal glass thicknesses alone cannot define mechanical performance.

The encapsulant does more than hold materials together. Its viscoelastic behaviour means that temperature and loading duration affect interlayer coupling. Research shows that encapsulant shear stiffness and interactions among materials influence module stresses and deflection.[4][5] The structural response observed in a short room-temperature test therefore cannot simply be transferred to hot conditions or sustained loading.

A stiffer encapsulant is not automatically better, either. Stronger coupling can increase overall stiffness while changing mechanical restraint and thermal stress in the cells. More encapsulant, a crossbar, or a thicker frame must be evaluated within the actual design, rather than treated as a universal reinforcement recipe for every 1.6 mm module.

Support span is particularly important for larger formats. A shorter span may reduce deformation but add rails, clamps, and installation work. Glass purchasing savings need to be included in the total module and system cost before a net saving can be established.

The module also passes through cooling after lamination. Differences in thermal expansion and mechanical restraint affect stresses after cooling and during later temperature changes.[5] Thickness changes therefore matter during material matching and process development, as well as during external load tests.

Figure 2. Glass-glass construction and composite action. Layer thicknesses and arrows are schematic. Encapsulant viscoelasticity, interface quality, and supports affect the response; encapsulant mass alone cannot predict module performance.[4][5]

Figure 2. Glass-glass construction and composite action. Layer thicknesses and arrows are schematic. Encapsulant viscoelasticity, interface quality, and supports affect the response; encapsulant mass alone cannot predict module performance.[4][5]

05 One certificate cannot answer every reliability question ​

Hail testing makes the issue tangible. The basic IEC 61215-2 combination uses a 25 mm ice ball at 23 m/s; the corresponding test velocity for 35 mm is 27.2 m/s.[6] For spherical ice balls of equal density, kinetic energy scales with diameter cubed and velocity squared. The second combination has approximately 3.84 times the theoretical energy of the first. A 40% increase in diameter represents a substantially different impact condition.

Hail-resistance statements should therefore identify diameter, velocity, impact locations, mounting boundaries, and acceptance results. Energy is only one part of impact severity and cannot by itself predict glass fracture. Different module designs with the same glass thickness cannot automatically share a test conclusion.

Static loading raises a similar issue. Unbroken glass under a specified test load such as 5,400 Pa does not establish that the cells are free from microcracks. Evaluation should consider visual inspection, EL, electrical performance, and safety-related results, while distinguishing test load from design load. Further assessment should address dynamic loading, transport vibration, and ageing after loading as appropriate to the application.

For service over 25 to 30 years, IEC 61215-1 explicitly states that qualification results are not a quantitative lifetime prediction.[7] Accelerated tests, manufacturing consistency, and field operation provide different parts of the evidence. The meaningful question is whether those results represent the same bill of materials, module format, and mounting arrangement that will actually be supplied.

During product introduction, comparing EL images, power changes, and failure locations before and after testing helps connect the evidence. Repeated cracking at one location calls for investigation of clamping, span, local flaws, and structural stress. A single pass or failure does not establish a conclusion for all 1.6 mm glass.

Figure 3. A 40% larger ice-ball diameter gives approximately 3.84 times the theoretical energy at these test velocities. Conditions are 25 mm at 23 m/s and 35 mm at 27.2 m/s. Equal-density spheres are assumed; this does not predict a module's hail-test outcome.[6]

Figure 3. A 40% larger ice-ball diameter gives approximately 3.84 times the theoretical energy at these test velocities. Conditions are 25 mm at 23 m/s and 35 mm at 27.2 m/s. Equal-density spheres are assumed; this does not predict a module's hail-test outcome.[6]

06 Put thickness back into the project selection process ​

For weight-sensitive roofs, calculate the added system load first, then compare handling, installation, and reliability outcomes across constructions. Large formats, long spans, and demanding wind or snow exposure require close examination of module mechanics and support conditions. Severe hail exposure requires more targeted impact evidence and may justify thicker front glass. A simple rule of thin glass for roofs and thick glass for ground-mounted systems is insufficient.

Four supplier questions are particularly useful: What strengthening state and batch controls apply to the supplied glass? Does the tested bill of materials match production? Which mounting conditions were used in load and hail reports? Which clamping zones, spans, and torques does the installation manual permit? These answers support engineering decisions more effectively than thickness alone.

An asymmetric construction can remain a candidate in the selection process. For example, 2.0 mm front glass and 1.6 mm rear glass give 9 kg/m² of glass at the density used above, between the two symmetric constructions. This is a design option to validate; its value depends on matching front protection, overall mechanics, and manufacturing conditions.

07 Conclusion ​

Our assessment is that 1.6 mm glass can enable lighter, less material-intensive modules that meet their reliability targets, opening additional options for weight-constrained applications. Whether it is worthwhile depends on the assembled module and the project conditions.

Mature lightweight design accounts for the glass saved, the manufacturing demands added, the structural response changed, and the resulting system benefit. The final object of evaluation should be a product solution supported by relevant evidence.

Data notes ​

Data notes: Verified on 16 November 2026. Glass mass uses a density of 2,500 kg/m³ and nominal thickness. The 32 kg module is a hypothetical example, not a product specification. Stiffness ratios use an individual thin-plate model with identical material properties. Relative ice-ball energy assumes equal-density spheres at the stated velocities. Product information follows a historical manufacturer announcement. The mechanics discussion explains influencing factors and does not replace product-specific structural analysis and validation.

References ​

[1] National Glass Association, Physical and Mechanical Properties of Typical Soda Lime Float Glass, FM05-12, 2023

[2] Trinasolar, Vertex S+ 505W n-type dual-glass modules enter mass production, 8 February 2024

[3] Effect of glass thickness on temperature gradient and stress distribution during glass tempering, Journal of Non-Crystalline Solids, 2016

[4] Bedon et al., Mechanical Analysis of the Quasi-Static and Dynamic Composite Action in PV Modules with Viscoelastic Encapsulant, Materials, 2024

[5] Beinert et al., Thermomechanical design rules for photovoltaic modules, Progress in Photovoltaics, 2023; first published online in 2022

[6] VDE SPEC 90038-2 V1.1, Section 5.24, Hail test, 6 December 2024

[7] IEC 61215-1:2021, Terrestrial photovoltaic modules — Design qualification and type approval — Part 1: Test requirements


PV Materials Lab

https://pvmaterialslab.com

A team with more than ten years of PV R&D and technical experience. Materials · Reliability · Failure analysis · Standards and certification · Products · Processes. AI + PV exchange and collaboration.

Statements: Original content reflects the authors’ views, is for reference, and is not investment advice. Sources are attributed. Some content uses AI assistance for figures, searches, and explanations; the core framework and key content are written by the technical team and reviewed by a human. Please contact us about factual errors or rights concerns.