15 kWh Is Only Six Weeks of Sun: NLR Sets an Outdoor Yardstick for Accelerated UV Testing

An NLR team in ACS Energy Letters quantified annual outdoor UV doses across the contiguous US: 72–133 kWh·m⁻² on the horizontal plane, median about 100. The 15 kWh·m⁻² of IEC 61215-2 MQT10 equals only 1.4–2.5 months outdoors, and trackers add another 10–18 per year. The paper also shows that fixed AM1.5G scaling underestimates outdoor UV, that 365 nm sources have a spectral blind spot, and proposes a five-item reporting checklist. Here is our brief summary and commentary from a module-reliability perspective.
Anyone in module reliability knows MQT10: a 15 kWh·m⁻² UV preconditioning step before thermal cycling and humidity freeze. Perovskite papers increasingly claim to have "passed X times the IEC UV test". But how long does 15 kWh·m⁻² take outdoors? A Perspective published in early November in ACS Energy Letters by NLR (formerly NREL) gives the answer: two and a half months at most.
01 Everyone's UV test uses a different ruler
The authors reviewed 33 UV-stability studies on perovskite solar cells and found almost no comparability: UV irradiance from 1 to 600 mW·cm⁻², exposure from 20 minutes to 2200 hours, and doses spanning more than four orders of magnitude. Seven studies report too little to compute a dose; the rest use five different conventions.
Three common ways of mapping lab doses to outdoor time each have a flaw:
- Multiples of MQT10: The most common. But MQT10 was written as a preconditioning step for c-Si modules, meant to reveal early packaging issues (encapsulant yellowing, delamination), not as a lifetime test.
- Fixed AM1.5G fraction: Assumes UV is always 4.6% of sunlight and multiplies annual insolation by 0.046. In reality the UV share varies with altitude, atmosphere and mounting.
- Irradiance and time only: Useful for mechanism studies, but cannot be placed on an outdoor time scale.
What the field lacks is not more tests, but a shared outdoor yardstick.
02 The yardstick: about 100 kWh·m⁻² per year in the US
Using National Solar Radiation Database (NSRDB) meteorology and a narrow-band spectral model, the authors computed annual 280–400 nm UV doses on a 1.5°×1.5° grid across the contiguous US for 2018–2024. Spectroradiometer data from Golden, Colorado and Eugene, Oregon validate the model, and results agree within about 5% with IEC 62788-7-2 benchmark sites.
- Range: Annual horizontal doses run from 72.1 (Washington State) to 133.3 kWh·m⁻² (southern New Mexico), median about 100 kWh·m⁻².
- UV share: UV is 5.5%–6.5% of GHI (median 5.9%), above AM1.5G's 4.6% everywhere. The spectrally resolved dose is 1.19–1.41 times the fixed-fraction estimate, most at high altitude.
- Global: With the same model, about 83% of global land falls within the US range; Berlin ~58, Beijing ~85, central Australia ~140, and the Andes up to 166 kWh·m⁻².

Figure 1 Annual horizontal UV dose by location vs. the MQT10 preconditioning dose
Takeaway: Estimating outdoor UV with AM1.5G's 4.6% is optimistic, i.e. non-conservative.
03 MQT10: barely more than a month outdoors
At the annual mean rate, 15 kWh·m⁻² accumulates outdoors in just 1.4–2.5 months anywhere in the contiguous US. A horizontal module placed on January 1 reaches it by early March in New Mexico, and by late April even in Washington State.
Measured against this yardstick, many "long-life" claims shrink:
| Lab exposure | Dose (kWh·m⁻²) | US horizontal outdoor equivalent |
|---|---|---|
| IEC 61215-2 MQT10 | 15 | 1.4–2.5 months |
| 30 h at 60 mW·cm⁻² | 18 | ~2 months (Golden) |
| A study's "5.4× IEC" | 81.6 | 7–14 months |
| One year at median US site | ~100 | 1 year (~6.7× MQT10) |
| IEC TS 63209-1 extended stress | 60–160 | ~6 months to 2+ years* |
Of 26 studies with a computable dose, 18 probe less than one outdoor year. Five of the six exceeding a year used 50–600 mW·cm⁻², 11–130 times the UV irradiance of AM1.5G, where sample heating can add degradation pathways absent outdoors.

Figure 2 Common lab UV doses expressed as US horizontal outdoor time
The paper offers a telling comparison: cells from Jiang et al. (Nature 2023) kept 94% efficiency after ~34 kWh·m⁻² indoors, yet only 66%–75% after 26 weeks outdoors, while receiving just 1.3–1.5 times the lab UV dose. UV can explain only a small part of the outdoor loss; heat under illumination dominated. With a dose yardstick, you can tell which stressor is the real culprit.
04 Two more variables: mounting and spectrum
Mounting matters as much as geography. Relative to horizontal, fixed tilt adds 2–5 kWh·m⁻² per year, single-axis tracking about 10, dual-axis about 18, and up to 35 at high-irradiance sites. Trackers follow the direct beam and see the most UV; steeper tilts gain little because they lose part of the diffuse sky, which carries a large share of UV.

Figure 3 Added annual UV dose by mounting configuration relative to horizontal
Spectrum is just as important. Outdoor UV is dominated by UV-A: below 320 nm contributes ~4%, below 340 nm ~22%, and 360–400 nm ~56%. A dose integrated only to 365 nm is about half of one integrated to 400 nm, so a dose without its spectral range can be off by a factor of two.

Figure 4 Band composition of the annual outdoor UV dose
Photon energy makes it clearer: about 19% of outdoor UV photons exceed 3.65 eV, while a 365 nm LED delivers only 3.40 eV, below the SnO₂ bandgap (3.6–4.0 eV) and at the lower bound of NiOₓ. No dose from a 365 nm source can probe an above-bandgap response in these oxide transport layers. Nine of the 13 p-i-n studies since 2025 used 365 nm alone. The authors therefore recommend full-spectrum sources such as UVA-340 fluorescent lamps or filtered xenon arcs.
Glass iron content and incidence angle also change the UV that reaches the cell, so reports should distinguish incident from transmitted dose.
05 The five-item reporting checklist
| Item | What to report | Why |
|---|---|---|
| Source spectrum | Source type and spectrum; dose in 280–320/320–340/340–360/360–400 nm bands; photon dose above the key layer's threshold | Shows which pathways the source can activate |
| Dose | Total dose, irradiance, time, detector; as a multiple of a stated annual outdoor dose | Places the test on an outdoor time scale |
| Duty cycle & temperature | Continuous or cycled; device temperature during exposure and dark rest; measured before or after dark rest | Separates reversible from permanent loss |
| Outdoor reference | Location and plane-of-array geometry assumed | Mounting shifts annual dose by up to 35 kWh·m⁻² |
| Device stack | Illuminated side, filters, glass type and Fe content; incident and transmitted dose | Separates the dose that reaches the absorber |
Note that the paper does not provide a table of recommended multiples. It suggests using 100 kWh·m⁻² (one horizontal year at a median US site) or 110 kWh·m⁻² (40° tilt in Golden per IEC 62788-7-2) as the reference year, with location and mounting stated. The dose maps and a conversion notebook are open on the NLR Data Catalog and GitHub.
06 Our view
There is no new device or record here; the value is in standardizing how doses are reported. Our observations:
- Not only a perovskite issue: UVID in c-Si TOPCon has been a hot topic. A typical 60 kWh·m⁻² extended UV test equals only ~0.6 years at a median US site. Marketing UVID resistance as "N times MQT10" deserves the same caution.
- Dose is not lifetime: The paper provides a dose scale, not an acceleration factor. Dose equivalence assumes reciprocity, which high irradiance, temperature and dark recovery can break; transferable conclusions still need action spectra.
- Front side only: Rear-side UV on bifacial modules, ground albedo, and coupling with damp heat and thermal cycling are not covered, yet bifacial-plus-tracker is the mainstream utility configuration in China.
- Missing China data: Only Beijing appears. High-altitude northwest China has a higher UV share; with trackers, annual doses may clearly exceed the US median. Localized dose maps are worth building.
Bottom line: Passing MQT10 only means passing UV preconditioning. To claim outdoor durability, report the spectrum and dose, and state how many years at which site and mounting.
07 Final thoughts
For labs, three immediate lessons: use full-spectrum sources (UVA-340 or filtered xenon) and report dose in four bands; measure actual device temperature and add a dark-recovery measurement; state the glass type and distinguish incident from transmitted dose. For module makers and buyers, when you see "X times IEC UV", ask: at the plant's location, is that months or years?
We will keep following progress on UVID and extended UV test methods, and welcome peers to share how their labs run UV tests.
Calculation notes / data basis
- "IEC TS 63209-1: ~6 months to 2+ years" is our estimate, dividing 60–160 kWh·m⁻² by the US annual extremes (133.3 and 72.1 kWh·m⁻²); it matches the range in the paper's Figure 3c.
- "60 kWh·m⁻² ≈ 0.6 years" assumes ~100 kWh·m⁻² per year on a horizontal plane at a median US site.
- Data in Figures 1–4 are taken from the paper and redrawn by us; location values are annual horizontal 280–400 nm doses.
References
- Witteck R., Nguyen Minh D., Owen-Bellini M., Luther J. M., Schelhas L. T. UV Exposure and Durability of Emerging Photovoltaics: Quantifying and Reporting Outdoor UV Doses. ACS Energy Letters, 2026. https://doi.org/10.1021/acsenergylett.6c02742
- IEC 61215-2:2021 Terrestrial PV modules – Design qualification and type approval – Part 2: Test procedures (MQT 10)
- IEC 62788-7-2:2017 Measurement procedures for materials used in PV modules – Part 7-2: Accelerated weathering tests of polymeric materials
- IEC TS 63209-1:2021 Photovoltaic modules – Extended-stress testing – Part 1: Modules
- Jiang Q. et al. Towards linking lab and field lifetimes of perovskite solar cells. Nature, 2023, 623, 313–318
- NLR Data Catalog: Outdoor UV Dose Maps and Site Data, https://doi.org/10.7799/17259481; conversion tool: https://github.com/NatLabRockies/pv-uv-dose
PV Materials Lab
PV Materials Lab
A PV R&D and technical team with 10+ years of experience | In-depth technical knowledge sharing
Materials · Reliability · Failure Analysis · Standards & Certification · Products · Processes
Exploring AI + PV — collaboration welcome
Disclaimer:
- Original content reflects the authors' personal views only, is for reference, and does not constitute investment advice.
- Reposted and cited content is credited to its source, with respect for original work.
- Some content is AI-assisted (chart generation, data retrieval, concept explanations, etc.); the core framework and key content are written by our technical team and reviewed by humans.
- For any inaccuracy or infringement, please leave a message or contact us.