Frame Structural Design: The Mechanics Behind the Cross-Section
PV Module Frame Series · 04

Frame walls can get thinner, but module deflection must not grow, and the answer lies in the cross-section. In the fourth article of our frame series, we treat the frame as a beam: why Face B height is worth more than wall thickness, how a closed C-cavity resists torsion, why long and short sides can differ, what new challenges large modules bring, and why the positions of mounting, grounding and drain holes are all compromises.
In Article 02 we left a conclusion: a stronger alloy raises strength, not stiffness. All aluminum alloys have an elastic modulus of about 69 GPa, so the only way to make a frame bend less is through the shape of its cross-section. In this article we start from mechanics and look at what Face B height, the C-cavity, long versus short sides and hole positions each solve.
01 Treat the frame as a beam
When a module is loaded by wind or snow, the load passes from the glass to the frame and from the frame to the mounting points. A long-side frame is therefore a beam resting on two mounting points, with a length overhanging at each end: the part between the mounting points is the span, and the parts outside are cantilevers.

Figure 1 Simplified mechanical model of the long-side frame
Mechanics of materials tells us that under a distributed load, beam deflection is roughly proportional to qL⁴/(EI), where q is the load, L the span, E the elastic modulus and I the section's moment of inertia. This expression contains the whole logic of frame design:
- E is essentially fixed: changing the aluminum alloy barely changes E, so this route is closed;
- L matters most: deflection scales with the fourth power of the span, so even a small shift in mounting points noticeably changes deflection;
- I is the design variable: the moment of inertia measures a section's resistance to bending and depends entirely on the section's shape and dimensions, which makes it the main battlefield of frame design.
02 Height is worth more than thickness
The moment of inertia has one key property: the farther material sits from the neutral axis (the line that neither stretches nor shortens when the section bends), the more it contributes. For a vertical wall, the moment of inertia scales with the cube of its height; for the horizontal flanges at top and bottom, the contribution scales with the square of their distance from the neutral axis.
So placing the same amount of aluminum farther from the neutral axis is more effective than simply thickening the walls. We estimated this with a simplified section, using 30 mm height and 1.5 mm wall thickness as the baseline:
| Face B height | Wall thickness | Moment of inertia | Aluminum per meter |
|---|---|---|---|
| 30 mm | 1.5 mm | 1.00× | 1.00× |
| 35 mm | 1.5 mm | 1.47× | 1.08× |
| 40 mm | 1.5 mm | 2.06× | 1.17× |
| 30 mm | 1.35 mm | 0.91× | 0.90× |
| 35 mm | 1.35 mm | 1.34× | 0.98× |

Figure 2 Effect of Face B height and wall thickness on moment of inertia and aluminum use (simplified-section estimate)
The last row is the most interesting: raising Face B from 30 mm to 35 mm while thinning the walls by 10% keeps aluminum use about the same yet raises stiffness by more than a third. That is why many cost-reduction designs do not simply thin the walls but raise the height and thin the walls together.
Height cannot grow without limit, of course. A taller Face B makes the module thicker, so fewer modules fit on each pallet in packing and transport, and the fit with racking and clamps must change too. All of this eats back part of the gain.
Takeaway: Frame stiffness comes down to the moment of inertia. The same aluminum is worth more the farther it sits from the neutral axis: raising Face B is often a better deal than thickening the walls.
03 The C-cavity and closed sections: resisting torsion, not just bending
A frame section is usually not a simple “L”. Face B, Face D and the top and bottom webs enclose a closed cavity, often called the C-cavity or profile cavity. Besides holding the corner keys, this cavity has another important job: resisting torsion.
Open sections (channels, L-shapes) twist easily, while a closed section's torsional stiffness is one or even several orders of magnitude higher. Under load, the force the glass exerts on the slot does not act through the section's shear center, so the frame bends and twists at the same time. If the section's torsional stiffness is insufficient, the frame rolls outward, the slot's grip on the glass weakens, and in severe cases the glass can pull out of the slot.

Figure 3 What each part of the frame section does
- Face A: holds the glass and carries the local pressure of clamps; too thin and it crushes, too tall and it traps dust and shades the module's lower edge;
- Slot: its height must match the laminate thickness plus silicone or tape; too loose and bonding is weak, too tight and framing becomes difficult;
- Faces B and D: enclose the cavity and form the main body resisting bending and torsion; Face B height sets most of the stiffness;
- Face C: the bottom flange carrying mounting and grounding holes; its width must suit bolts and clamps;
- Ribs: strips added inside the cavity or on flanges raise local stiffness with little aluminum and prevent thin walls from buckling.
04 Different long and short sides: aluminum where it counts
With the most common long-side mounting, the long-side frame is the main load-bearing beam and sees large bending moments. The short-side frame mainly restrains the glass edge and carries load along the short direction to the corners, with much smaller moments. Since the loads differ, the sections need not be the same.
This has led to differentiated long and short sides: the long side uses a taller, thicker section for stiffness, while the short side uses a lower, thinner section to save aluminum. It is one of the common ways to cut frame cost.
But differentiation rests on two conditions. First, the mounting method must be controlled: if the site switches to short-side mounting or landscape mounting, the short side becomes the main beam and the original design no longer applies. Second, the corner keys and corner joints must match: with different long and short sections, corner loads and assembly accuracy must be re-verified. So for modules with differentiated frames, the installation manual must clearly restrict the mounting method.
05 Large modules: bigger loads, more challenges
In July 2023, nine leading module makers reached a consensus to standardize the size of mid-format rectangular-wafer modules at 2382 mm × 1134 mm. Such a module has an area of about 2.7 m². At 2400 Pa it carries a total load of about 6.5 kN, and at 5400 Pa about 14.6 kN, equivalent to roughly 1.5 tonnes pressing on one module.
The effect of larger size is stronger than the increase in area suggests. Deflection scales with the fourth power of span, so a 5% longer span means about 22% more deflection. Add ever-thinner glass in glass-glass modules, which can share only limited stiffness, and the frame's burden keeps growing.
The main countermeasures are a taller Face B, double or multi-cavity sections, and ribs at key positions. In heavy-snow regions, a back support bar can also be fitted behind the module to share part of the mid-span load of the long sides. Every option must balance stiffness, weight, cost and installation compatibility.
Bottom line: The real test large modules pose for frames is not area but span. The fourth-power effect of span is the first number any weight-reduction plan must work out.
06 Hole positions: every hole is a compromise
Holes in a frame look like a small matter, but each one trades function against strength:

Figure 4 Mounting hole positions on the long-side frame (per the standardization consensus)
- Mounting holes: under the standardization consensus, the longitudinal hole spacings on the long side are 400 mm, 790 mm and 1400 mm. With 1400 mm spacing, the holes sit about 491 mm from each end, about 0.21 of the length. A classic result of beam mechanics says that under a uniform load, supports placed about 0.207 of the length from each end make the mid-span moment equal to the moment at the supports, minimizing the beam's maximum moment. The standard hole position falls almost exactly there;
- Grounding holes: should be near the mounting points and clearly marked for easy field wiring, with protection after the anodic film is pierced;
- Drain holes: go at the lowest point after installation, usually near the corners, to keep the cavity from collecting water that freezes and cracks the frame;
- The cost of a hole: holes sit on the Face C flange, which is farthest from the neutral axis and sees the highest bending stress; hole edges concentrate stress, so holes should avoid the zones of maximum moment.
In addition, hole walls are bare aluminum, and as Article 03 explained, they are often where corrosion appears first. Hole positions affect not only strength but also long-term reliability.
07 Final thoughts
To wrap up this article:
- The frame is a beam: deflection depends on load, span, elastic modulus and moment of inertia, and the moment of inertia is the main design battlefield;
- Height beats thickness: a taller Face B with thinner walls can raise stiffness markedly while keeping aluminum use about the same;
- Closed sections resist torsion: the C-cavity not only holds corner keys but stops the frame rolling over under load;
- Differentiated long and short sides: put the aluminum where the load is highest, but the mounting method must be controlled;
- Holes are compromises: mounting, grounding and drain holes must balance function, strength and corrosion.
Once the design is drawn, it still has to be made. In the next article we cover frame manufacturing: the steps from aluminum billet to finished frame, how to choose corner keys, and how to control dimensional tolerances, hardness and burrs. Stay tuned.
Calculation notes / data basis
- Moment of inertia and aluminum use are our estimates for a simplified section made of five rectangles (Face B, Face A, slot floor, Face D and Face C), with Face A and cavity 20 mm wide, slot 8 mm high and Face C 30 mm wide; only Face B height and wall thickness vary. Real frame sections are more complex and absolute values will differ; the table only shows relative trends.
- Module area is 2382 mm × 1134 mm ≈ 2.70 m². Total load = pressure × area: 2400 Pa × 2.70 m² ≈ 6.5 kN; 5400 Pa × 2.70 m² ≈ 14.6 kN. With g = 9.8 m/s², 14.6 kN is roughly the weight of 1.5 tonnes.
- Deflection scales with the fourth power of span: 1.05⁴ ≈ 1.22, so a 5% longer span gives about 22% more deflection, all else equal.
- Distance from mounting hole to frame end = (2382 − 1400) ÷ 2 ≈ 491 mm, about 0.21 of the length; 0.207 = (√2 − 1)/2 is the theoretical support position that minimizes the maximum moment of a uniformly loaded beam with two overhangs.
References
- 中国证券报·中证网. 9家光伏组件企业就矩形硅片中版型组件尺寸标准化达成共识, 2023-07-07. https://www.cs.com.cn/xwzx/hg/202307/t20230707_6354611.html
- Yicai Global. Three leading companies announce 2382*1134 standard size components with 66 version batteries, 2023. https://www.yicaiglobal.com/star50news/2023_07_296583380069685657608
- T/CPIA 0003-2022 地面用晶体硅光伏组件外形尺寸及安装孔技术要求 / Dimensions and mounting holes of crystalline silicon PV modules (CPIA group standard)
- IEC 61215-2:2021 Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 2: Test procedures (MQT 16, MQT 20)
- T/SHLX 005—2024 太阳能电池边框用铝合金型材 / Aluminum alloy extruded profiles for solar cell frames
PV Materials Lab
https://pvmaterialslab.com
PV Materials Lab
A PV R&D and technical team with 10+ years of experience | In-depth technical knowledge sharing
Materials · Reliability · Failure Analysis · Standards & Certification · Products · Processes
Exploring AI + PV — collaboration welcome
Disclaimer:
- Original content reflects the authors' personal views only, is for reference, and does not constitute investment advice.
- Reposted and cited content is credited to its source, with respect for original work.
- Some content is AI-assisted (chart generation, data retrieval, concept explanations, etc.); the core framework and key content are written by our technical team and reviewed by humans.
- For any inaccuracy or infringement, please leave a message or contact us.